| System Specifications - 1U |
| Form Factor: |
1U rack height |
| Processors: |
Up to two Quad-Core or Dual-Core Intel® Xeon® Processor 5500 Series |
| Processor Sockets: |
2 |
| Interconnect: |
Intel® QuickPath Interconnect (QPI) |
| L2/L3 Cache: |
4MB and 8MB |
| Chipset: |
Intel® 5520 |
| Memory: |
Up to 96GB (12 DIMM slots/6 per-processor): 1GB/2GB/4GB/8GB DDR3 800MHz, 1066MHz or 1333MHz |
| I/O Slots: |
Two x8 Gen2 slots |
| Drive Controller: |
PERC6/i or SAS6/iR, PERC 5/E and PERC 6/E |
| RAID Controller: |
Optional PERC 6/i integrated SAS/SATA daughtercard controller with 256MB cache, PERC 5/e adapter, PERC 6/i and SAS 6/iR PERC 6i utilizing battery backed 256MB DDRII 667 |
| Drive Bays: |
Internal hard drive bay and hot-plug backplane.
Up to six 2.5" SAS, or SSD Drives |
| Max. Internal Storage: |
|
| Hard Drives: |
2.5" SAS (15K RPM): 73GB, 146GB
2.5" SAS (10K RPM): 73GB, 146GB, 300GB
2.5" SSD: 25GB, 50GB |
| Network Interface Cards: |
Two dual port embedded Broadcom® NetXtreme II™ 5709c Gigabit Ethernet NIC with failover and load balancing. Optional 1GBe and 10GBe add-in NICs
|
| Power Supply: |
Two hot-plug high-efficient 502W Energy Smart PSU or two hot-plug 717W High Output PSUs |
| Availability: |
DDR3 memory; ECC; hot-plug hard drives; optional hot-plug redundant power supplies; dual embedded NICs with failover and load balancing support; optional PERC6/i integrated daughtercard controller with battery-backed cache; hot-plug redundant cooling; tool-less chassis; fibre and SAS cluster support; validated for Dell/EMC SAN |
| Video: |
Integrated Matrox G200, 8MB shared video memory |
| Remote Management: |
iDRAC6 |
| Systems Management: |
Dell™ OpenManage™ |
| Fans: |
Standard redundant cooling |
| Acoustics: |
Typically configured* 2.5" chassis in 23 ± 2 C ambient
Idle: LwA-UL** = 5.3 bels, LpAm*** = 35 dBA |
| Rack Support: |
Support for sliding ReadyRails™ for 4-post Racks and Static ReadyRails™ for 4-post & 2-post Racks |
| System Specifications - 3U |
| Drives and Capacity |
| Hard Disk Drives: |
Up to fifteen (15) 3.5-inch SAS or SATA hot-pluggable hard disk drives |
Drive Performance
and Capacities: |
15,000 RPM SAS drives available in 73GB, 146GB, 300GB, 450GB and 600GB
10,000 RPM SAS drives available in 300GB, 400GB and 600GB
Nearline SAS (7,200 RPM) drives available in 500GB, 750GB or 1TB
7,200 RPM SATA II drives available in 250GB, 500GB, 750GB, 1TB and 2TB
Energy efficient SATA II (5,400 RPM) drives available in 1TB and 2TB |
| Maximum Capacity Per Enclosure: |
1.1TB using fifteen (15) 73GB 15K SAS disk drives |
| Maximum Capacity Per Enclosure: |
30TB using fifteen (15) 2TB disk drives |
| Host Connectivity |
| Unified Mode: |
Direct connectivity to 15 disk drives and beyond |
| Split Mode – Dual Host access: |
Connectivity to drives 0 though 6 to one host; A separate connectivity to drives 7 through 14 to the second host. |
| Enclosure Management Modules and RAID Levels |
| Enclosure Management Modules (EMMs): |
1 or 2 hot-pluggable management modules |
| RAID Levels: |
PERC 5/E Supports RAID levels 0, 1, 5, 10, 50
PERC 6/E Supports RAID levels 0, 1, 5, 6, 10, 50, 60
Up to 30 physical disks per group
Up to 256 virtual disks |
| Back-Panel Connectors (per EMM) |
| Host Connectivity: |
One x4 3GB SAS (SFF 8470) |
| Expansion Connectivity: |
One x4 3GB SAS (SFF 8470)
|
| Service Management: |
One 6-pin UART mini-DIN connector |
| LED Indicators |
| Front Panel: |
1 Two-color LED indicator for system status, 2 single-color LED indicators for power and split mod |
| Hard Drive Carrier: |
1 single-color activity LED, 1 two-color LED status indicator per drive |
| EMM: |
3 two-color LED status indicators: one for each of the EMM SAS ports and one for the EMM status |
| Power Supply/Cooling Fan Module: |
3 LED status indicators for power supply status, power/supply/fan fault and AC status |
| Power Supplies (per supply) |
| Wattage: |
478W (Maximum continuous); 550W (peak) |
| Maximum Heat Dissipation: |
1430 BTU/hour (maximum) |
| Input Voltage Range: |
100-240V rated (actual 90-26V) |
| Frequency Range: |
47-63Hz |
| Amperage: |
7.2A at 100V, 3.6A at 200V |
| Available Hard Drive Power (per slot) |
| Supported Continuous Consumption: |
Up to 1.3A +12V; Up to 1.5A at +5V |
| Physical |
| Height x Width x Depth: |
13.11 cm (5.16 inches) x 44.63 cm (17.57 inches) x 48.01cm (18.90 inches) |
| Weight: |
35.37 km (78 lbs) (maximum configuration) |
| Environmental |
| Temperature: |
Operating: 10° to 35°C (50° to 95°F), Storage : -40° to 65°C (-40° to 149°F) |
| Relative Humidity: |
Operating: 20% to 80% (non-condensing), Storage: 5% to 95% (non-condensing) |
| Altitude: |